Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
Int J Cardiol ; : 132061, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641263

RESUMO

BACKGROUND AND AIMS: Intracoronary pressure gradients and translesional flow patterns have been correlated with coronary plaque progression and lesion destabilization. In this study, we aimed to determine the relationship between endothelial shear stress and plaque progression and to evaluate the effect of shear forces on coronary plaque features. METHODS: A systematic review was conducted in medical on-line databases. Selected were studies including human participants who underwent coronary anatomy assessment with computational fluid dynamics (CFD)-based wall shear stress (WSS) calculation at baseline with anatomical evaluation at follow-up. A total of six studies were included for data extraction and analysis. RESULTS: The meta-analysis encompassed 31'385 arterial segments from 136 patients. Lower translesional WSS values were significantly associated with a reduction in lumen area (mean difference -0.88, 95% CI -1.13 to -0.62), an increase in plaque burden (mean difference 4.32, 95% CI 1.65 to 6.99), and an increase in necrotic core area (mean difference 0.02, 95% CI 0.02 to 0.03) at follow-up imaging. Elevated WSS values were associated with an increase in lumen area (mean difference 0.78, 95% CI 0.34 to 1.21) and a reduction in both fibrofatty (mean difference -0.02, 95% CI -0.03 to -0.01) and fibrous plaque areas (mean difference -0.03, 95% CI -0.03 to -0.03). CONCLUSION: This meta-analysis shows that WSS parameters were related to vulnerable plaque features at follow-up. These results emphasize the impact of endothelial shear forces on coronary plaque growth and composition. Future studies are warranted to evaluate the role of WSS in guiding clinical decision-making.

2.
Med Eng Phys ; 126: 104144, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621846

RESUMO

The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.


Assuntos
Fenômenos Fisiológicos Cardiovasculares , Smartphone , Reologia/métodos , Velocidade do Fluxo Sanguíneo , Imagens de Fantasmas
3.
Artif Intell Med ; 151: 102841, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38658130

RESUMO

BACKGROUND AND OBJECTIVE: In everyday clinical practice, medical decision is currently based on clinical guidelines which are often static and rigid, and do not account for population variability, while individualized, patient-oriented decision and/or treatment are the paradigm change necessary to enter into the era of precision medicine. Most of the limitations of a guideline-based system could be overcome through the adoption of Clinical Decision Support Systems (CDSSs) based on Artificial Intelligence (AI) algorithms. However, the black-box nature of AI algorithms has hampered a large adoption of AI-based CDSSs in clinical practice. In this study, an innovative AI-based method to compress AI-based prediction models into explainable, model-agnostic, and reduced decision support systems (NEAR) with application to healthcare is presented and validated. METHODS: NEAR is based on the Shapley Additive Explanations framework and can be applied to complex input models to obtain the contributions of each input feature to the output. Technically, the simplified NEAR models approximate contributions from input features using a custom library and merge them to determine the final output. Finally, NEAR estimates the confidence error associated with the single input feature contributing to the final score, making the result more interpretable. Here, NEAR is evaluated on a clinical real-world use case, the mortality prediction in patients who experienced Acute Coronary Syndrome (ACS), applying three different Machine Learning/Deep Learning models as implementation examples. RESULTS: NEAR, when applied to the ACS use case, exhibits performances like the ones of the AI-based model from which it is derived, as in the case of the Adaptive Boosting classifier, whose Area Under the Curve is not statistically different from the NEAR one, even the model's simplification. Moreover, NEAR comes with intrinsic explainability and modularity, as it can be tested on the developed web application platform (https://neardashboard.pythonanywhere.com/). CONCLUSIONS: An explainable and reliable CDSS tailored to single-patient analysis has been developed. The proposed AI-based system has the potential to be used alongside the clinical guidelines currently employed in the medical setting making them more personalized and dynamic and assisting doctors in taking their everyday clinical decisions.


Assuntos
Algoritmos , Inteligência Artificial , Sistemas de Apoio a Decisões Clínicas , Sistemas de Apoio a Decisões Clínicas/organização & administração , Humanos
4.
Artigo em Inglês | MEDLINE | ID: mdl-38551602

RESUMO

BACKGROUND: Arterial stiffness, particularly aortic stiffness (AoS), is associated with an increased risk of cardiovascular disease. Endovascular repair for abdominal (EVAR) and thoracic (TEVAR) aortic disease may increase AoS. This study protocol aims to assess changes in AoS before and after interventions for aortic disease. METHODS: Patients scheduled for EVAR or TEVAR during a three-year period will be enrolled. An indirect AoS indicator, carotid-to-femoral pulse wave velocity (cf-PWV) will be measured non-invasively using applanation tonometry and reported with others perioperative data before and after the endovascular treatment. Moreover, cardiological data will be collected through echocardiography. RESULTS: Fifty EVAR and 50 TEVAR will be enrolled. We will primarily analyze changes in cf-PWV. To ensure the reliability of our findings, we will also include supplementary data such as clinical information, morphological data, and functional echocardiographic data. CONCLUSIONS: By examining AoS modifications before and after endovascular aortic repair, this study aims to enhance our understanding of how arterial stiffness changes following endoprosthesis deployment. The findings from the applied protocol are expected to be informative for innovative graft designs with minimized mechanical mismatch with the aortic wall and with improved vascular hemodynamic, aligning with the current trend in improving patient outcomes. Moreover, understanding these modifications is important for predicting and improving long-term cardiovascular outcomes in patients undergoing such interventions.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38427153

RESUMO

This study focuses on identifying anatomical markers with predictive capacity for long-term myocardial infarction (MI) in focal coronary artery disease (CAD). Eighty future culprit lesions (FCL) and 108 non-culprit lesions (NCL) from 80 patients underwent 3D quantitative coronary angiography. The minimum lumen area (MLA), minimum lumen ratio (MLR), and vessel fractional flow reserve (vFFR) were evaluated. MLR was defined as the ratio between MLA and the cross-sectional area at the proximal lesion edge, with lower values indicating more abrupt luminal narrowing. Significant differences were observed between FCL and NCL in MLR (0.41 vs. 0.53, p < 0.001). MLR correlated inversely with translesional vFFR (r = - 0.26, p = 0.0004) and was the strongest predictor of MI at 5 years (AUC = 0.75). Lesions with MLR < 0.40 had a fourfold increased MI incidence at 5 years. MLR is a robust predictor of future adverse coronary events.

6.
Ann Vasc Surg ; 104: 237-247, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492732

RESUMO

BACKGROUND: Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS: Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS: An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS: ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.

7.
Arterioscler Thromb Vasc Biol ; 44(4): 976-986, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38328935

RESUMO

BACKGROUND: Plaque composition and wall shear stress (WSS) magnitude act as well-established players in coronary plaque progression. However, WSS magnitude per se does not completely capture the mechanical stimulus to which the endothelium is subjected, since endothelial cells experience changes in the WSS spatiotemporal configuration on the luminal surface. This study explores WSS profile and lipid content signatures of plaque progression to identify novel biomarkers of coronary atherosclerosis. METHODS: Thirty-seven patients with acute coronary syndrome underwent coronary computed tomography angiography, near-infrared spectroscopy intravascular ultrasound, and optical coherence tomography of at least 1 nonculprit vessel at baseline and 1-year follow-up. Baseline coronary artery geometries were reconstructed from intravascular ultrasound and coronary computed tomography angiography and combined with flow information to perform computational fluid dynamics simulations to assess the time-averaged WSS magnitude (TAWSS) and the variability in the contraction/expansion action exerted by WSS on the endothelium, quantifiable in terms of topological shear variation index (TSVI). Plaque progression was measured as intravascular ultrasound-derived percentage plaque atheroma volume change at 1-year follow-up. Plaque composition information was extracted from near-infrared spectroscopy and optical coherence tomography. RESULTS: Exposure to high TSVI and low TAWSS was associated with higher plaque progression (4.00±0.69% and 3.60±0.62%, respectively). Plaque composition acted synergistically with TSVI or TAWSS, resulting in the highest plaque progression (≥5.90%) at locations where lipid-rich plaque is exposed to high TSVI or low TAWSS. CONCLUSIONS: Luminal exposure to high TSVI, solely or combined with a lipid-rich plaque phenotype, is associated with enhanced plaque progression at 1-year follow-up. Where plaque progression occurred, low TAWSS was also observed. These findings suggest TSVI, in addition to low TAWSS, as a potential biomechanical predictor for plaque progression, showing promise for clinical translation to improve patient prognosis.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Vasos Coronários/diagnóstico por imagem , Células Endoteliais , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Lipídeos , Estresse Mecânico , Angiografia Coronária
8.
Sci Rep ; 14(1): 1722, 2024 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-38242930

RESUMO

Intrinsic permeability describes the ability of a porous medium to be penetrated by a fluid. Considering porous scaffolds for tissue engineering (TE) applications, this macroscopic variable can strongly influence the transport of oxygen and nutrients, the cell seeding process, and the transmission of fluid forces to the cells, playing a crucial role in determining scaffold efficacy. Thus, accurately measuring the permeability of porous scaffolds could represent an essential step in their optimization process. In literature, several methods have been proposed to characterize scaffold permeability. Most of the currently adopted approaches to assess permeability limit their applicability to specific scaffold structures, hampering protocols standardization, and ultimately leading to incomparable results among different laboratories. The content of novelty of this study is in the proposal of an adaptable test bench and in defining a specific testing protocol, compliant with the ASTM International F2952-22 guidelines, for reliable and repeatable measurements of the intrinsic permeability of TE porous scaffolds. The developed permeability test bench (PTB) exploits the pump-based method, and it is composed of a modular permeability chamber integrated within a closed-loop hydraulic circuit, which includes a peristaltic pump and pressure sensors, recirculating demineralized water. A specific testing protocol was defined for characterizing the pressure drop associated with the scaffold under test, while minimizing the effects of uncertainty sources. To assess the operational capabilities and performance of the proposed test bench, permeability measurements were conducted on PLA scaffolds with regular (PS) and random (RS) micro-architecture and on commercial bovine bone matrix-derived scaffolds (CS) for bone TE. To validate the proposed approach, the scaffolds were as well characterized using an alternative test bench (ATB) based on acoustic measurements, implementing a blind randomized testing procedure. The consistency of the permeability values measured using both the test benches demonstrated the reliability of the proposed approach. A further validation of the PTB's measurement reliability was provided by the agreement between the measured permeability values of the PS scaffolds and the theory-based predicted permeability value. Once validated the proposed PTB, the performed measurements allowed the investigation of the scaffolds' transport properties. Samples with the same structure (guaranteed by the fused-deposition modeling technique) were characterized by similar permeability values, and CS and RS scaffolds showed permeability values in agreement with the values reported in the literature for bovine trabecular bone. In conclusion, the developed PTB and the proposed testing protocol allow the characterization of the intrinsic permeability of porous scaffolds of different types and dimensions under controlled flow regimes, representing a powerful tool in view of providing a reliable and repeatable framework for characterizing and optimizing scaffolds for TE applications.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Animais , Bovinos , Engenharia Tecidual/métodos , Porosidade , Reprodutibilidade dos Testes , Alicerces Teciduais/química , Permeabilidade
9.
Ann Biomed Eng ; 52(2): 226-238, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37733110

RESUMO

The present study establishes a link between blood flow energy transformations in coronary atherosclerotic lesions and clinical outcomes. The predictive capacity for future myocardial infarction (MI) was compared with that of established quantitative coronary angiography (QCA)-derived predictors. Angiography-based computational fluid dynamics (CFD) simulations were performed on 80 human coronary lesions culprit of MI within 5 years and 108 non-culprit lesions for future MI. Blood flow energy transformations were assessed in the converging flow segment of the lesion as ratios of kinetic and rotational energy values (KER and RER, respectively) at the QCA-identified minimum lumen area and proximal lesion sections. The anatomical and functional lesion severity were evaluated with QCA to derive percentage area stenosis (%AS), vessel fractional flow reserve (vFFR), and translesional vFFR (ΔvFFR). Wall shear stress profiles were investigated in terms of topological shear variation index (TSVI). KER and RER predicted MI at 5 years (AUC = 0.73, 95% CI 0.65-0.80, and AUC = 0.76, 95% CI 0.70-0.83, respectively; p < 0.0001 for both). The predictive capacity for future MI of KER and RER was significantly stronger than vFFR (p = 0.0391 and p = 0.0045, respectively). RER predictive capacity was significantly stronger than %AS and ΔvFFR (p = 0.0041 and p = 0.0059, respectively). The predictive capacity for future MI of KER and RER did not differ significantly from TSVI. Blood flow kinetic and rotational energy transformations were significant predictors for MI at 5 years (p < 0.0001). The findings of this study support the hypothesis of a biomechanical contribution to the process of plaque destabilization/rupture leading to MI.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Humanos , Vasos Coronários , Angiografia Coronária , Valor Preditivo dos Testes , Índice de Gravidade de Doença
10.
Int J Cardiol ; 399: 131668, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38141723

RESUMO

BACKGROUND AND AIMS: Coronary hemodynamics impact coronary plaque progression and destabilization. The aim of the present study was to establish the association between focal vs. diffuse intracoronary pressure gradients and wall shear stress (WSS) patterns with atherosclerotic plaque composition. METHODS: Prospective, international, single-arm study of patients with chronic coronary syndromes and hemodynamic significant lesions (fractional flow reserve [FFR] ≤ 0.80). Motorized FFR pullback pressure gradient (PPG), optical coherence tomography (OCT), and time-average WSS (TAWSS) and topological shear variation index (TSVI) derived from three-dimensional angiography were obtained. RESULTS: One hundred five vessels (median FFR 0.70 [Interquartile range (IQR) 0.56-0.77]) had combined PPG and WSS analyses. TSVI was correlated with PPG (r = 0.47, [95% Confidence Interval (95% CI) 0.30-0.65], p < 0.001). Vessels with a focal CAD (PPG above the median value of 0.67) had significantly higher TAWSS (14.8 [IQR 8.6-24.3] vs. 7.03 [4.8-11.7] Pa, p < 0.001) and TSVI (163.9 [117.6-249.2] vs. 76.8 [23.1-140.9] m-1, p < 0.001). In the 51 vessels with baseline OCT, TSVI was associated with plaque rupture (OR 1.01 [1.00-1.02], p = 0.024), PPG with the extension of lipids (OR 7.78 [6.19-9.77], p = 0.003), with the presence of thin-cap fibroatheroma (OR 2.85 [1.11-7.83], p = 0.024) and plaque rupture (OR 4.94 [1.82 to 13.47], p = 0.002). CONCLUSIONS: Focal and diffuse coronary artery disease, defined using coronary physiology, are associated with differential WSS profiles. Pullback pressure gradients and WSS profiles are associated with atherosclerotic plaque phenotypes. Focal disease (as identified by high PPG) and high TSVI are associated with high-risk plaque features. CLINICAL TRIAL REGISTRATION: https://clinicaltrials,gov/ct2/show/NCT03782688.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica , Fenótipo , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos
11.
JACC Cardiovasc Interv ; 16(19): 2396-2408, 2023 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-37821185

RESUMO

BACKGROUND: Low fractional flow reserve (FFR) after percutaneous coronary intervention (PCI) has been associated with adverse clinical outcomes. Hitherto, this assessment has been independent of the epicardial vessel interrogated. OBJECTIVES: This study sought to assess the predictive capacity of post-PCI FFR for target vessel failure (TVF) stratified by coronary artery. METHODS: We performed a systematic review and individual patient-level data meta-analysis of randomized clinical trials and observational studies with protocol-recommended post-PCI FFR assessment. The difference in post-PCI FFR between left anterior descending (LAD) and non-LAD arteries was assessed using a random-effect models meta-analysis of mean differences. TVF was defined as a composite of cardiac death, target vessel myocardial infarction, and clinically driven target vessel revascularization. RESULTS: Overall, 3,336 vessels (n = 2,760 patients) with post-PCI FFR measurements were included in 9 studies. The weighted mean post-PCI FFR was 0.89 (95% CI: 0.87-0.90) and differed significantly between coronary vessels (LAD = 0.86; 95% CI: 0.85 to 0.88 vs non-LAD = 0.93; 95% CI: 0.91-0.94; P < 0.001). Post-PCI FFR was an independent predictor of TVF, with its risk increasing by 52% for every reduction of 0.10 FFR units, and this was mainly driven by TVR. The predictive capacity for TVF was poor for LAD arteries (AUC: 0.52; 95% CI: 0.47-0.58) and moderate for non-LAD arteries (AUC: 0.66; 95% CI: 0.59-0.73; LAD vs non-LAD arteries, P = 0.005). CONCLUSIONS: The LAD is associated with a lower post-PCI FFR than non-LAD arteries, emphasizing the importance of interpreting post-PCI FFR on a vessel-specific basis. Although a higher post-PCI FFR was associated with improved prognosis, its predictive capacity for events differs between the LAD and non-LAD arteries, being poor in the LAD and moderate in the non-LAD vessels.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Angiografia Coronária , Resultado do Tratamento , Valor Preditivo dos Testes
12.
Comput Methods Programs Biomed ; 242: 107823, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37757568

RESUMO

BACKGROUND: The combination of medical imaging and computational hemodynamics is a promising technology to diagnose/prognose coronary artery disease (CAD). However, the clinical translation of in silico hemodynamic models is still hampered by assumptions/idealizations that must be introduced in model-based strategies and that necessarily imply uncertainty. This study aims to provide a definite answer to the open question of how to properly model blood rheological properties in computational fluid dynamics (CFD) simulations of coronary hemodynamics. METHODS: The geometry of the right coronary artery (RCA) of 144 hemodynamically stable patients with different stenosis degree were reconstructed from angiography. On them, unsteady-state CFD simulations were carried out. On each reconstructed RCA two different simulation strategies were applied to account for blood rheological properties, implementing (i) a Newtonian (N) and (ii) a shear-thinning non-Newtonian (non-N) rheological model. Their impact was evaluated in terms of wall shear stress (WSS magnitude, multidirectionality, topological skeleton) and helical flow (strength, topology) profiles. Additionally, luminal surface areas (SAs) exposed to shear disturbances were identified and the co-localization of paired N and non-N SAs was quantified in terms of similarity index (SI). RESULTS: The comparison between paired N vs. shear-thinning non-N simulations revealed remarkably similar profiles of WSS-based and helicity-based quantities, independent of the adopted blood rheology model and of the degree of stenosis of the vessel. Statistically, for each paired N and non-N hemodynamic quantity emerged negligible bias from Bland-Altman plots, and strong positive linear correlation (r > 0.94 for almost all the WSS-based quantities, r > 0.99 for helicity-based quantities). Moreover, a remarkable co-localization of N vs. non-N luminal SAs exposed to disturbed shear clearly emerged (SI distribution 0.95 [0.93, 0.97]). Helical flow topology resulted to be unaffected by blood rheological properties. CONCLUSIONS: This study, performed on 288 angio-based CFD simulations on 144 RCA models presenting with different degrees of stenosis, suggests that the assumptions on blood rheology have negligible impact both on WSS and helical flow profiles associated with CAD, thus definitively answering to the question "is Newtonian assumption for blood rheology adequate in coronary hemodynamics simulations?".


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Humanos , Vasos Coronários/diagnóstico por imagem , Constrição Patológica , Hemodinâmica , Reologia , Doença da Artéria Coronariana/diagnóstico por imagem , Modelos Cardiovasculares , Estresse Mecânico , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador
13.
Front Cardiovasc Med ; 10: 1216796, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37719972

RESUMO

Background: Computational fluid dynamics (CFD) is emerging as an effective technology able to improve procedural outcomes and enhance clinical decision-making in patients with coronary artery disease (CAD). The present study aims to assess the state of knowledge, use and clinical acceptability of CFD in the diagnosis and treatment of CAD. Methods: We realized a 20-questions international, anonymous, cross-sectional survey to cardiologists to test their knowledge and confidence on CFD as a technology applied to patients suffering from CAD. Responses were recorded between May 18, 2022, and June 12, 2022. Results: A total of 466 interventional cardiologists (mean age 48.4 ± 8.3 years, males 362), from 42 different countries completed the survey, for a response rate of 45.9%. Of these, 66.6% declared to be familiar with the term CFD, especially for optimization of existing interventional techniques (16.1%) and assessment of hemodynamic quantities related with CAD (13.7%). About 30% of respondents correctly answered to the questions exploring their knowledge on the pathophysiological role of some CFD-derived quantities such as wall shear stress and helical flow in coronary arteries. Among respondents, 85.9% would consider patient-specific CFD-based analysis in daily interventional practice while 94.2% declared to be interested in receiving a brief foundation course on the basic CFD principles. Finally, 87.7% of respondents declared to be interested in a cath-lab software able to conduct affordable CFD-based analyses at the point-of-care. Conclusions: Interventional cardiologists reported to be profoundly interested in adopting CFD simulations as a technology supporting decision making in the treatment of CAD in daily practice.

15.
J Biomech ; 154: 111620, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37178494

RESUMO

In the context of aortic hemodynamics, uncertainties affecting blood flow simulations hamper their translational potential as supportive technology in clinics. Computational fluid dynamics (CFD) simulations under rigid-walls assumption are largely adopted, even though the aorta contributes markedly to the systemic compliance and is characterized by a complex motion. To account for personalized wall displacements in aortic hemodynamics simulations, the moving-boundary method (MBM) has been recently proposed as a computationally convenient strategy, although its implementation requires dynamic imaging acquisitions not always available in clinics. In this study we aim to clarify the real need for introducing aortic wall displacements in CFD simulations to accurately capture the large-scale flow structures in the healthy human ascending aorta (AAo). To do that, the impact of wall displacements is analyzed using subject-specific models where two CFD simulations are performed imposing (1) rigid walls, and (2) personalized wall displacements adopting a MBM, integrating dynamic CT imaging and a mesh morphing technique based on radial basis functions. The impact of wall displacements on AAo hemodynamics is analyzed in terms of large-scale flow patterns of physiological significance, namely axial blood flow coherence (quantified applying the Complex Networks theory), secondary flows, helical flow and wall shear stress (WSS). From the comparison with rigid-wall simulations, it emerges that wall displacements have a minor impact on the AAo large-scale axial flow, but they can affect secondary flows and WSS directional changes. Overall, helical flow topology is moderately affected by aortic wall displacements, whereas helicity intensity remains almost unchanged. We conclude that CFD simulations with rigid-wall assumption can be a valid approach to study large-scale aortic flows of physiological significance.


Assuntos
Aorta Torácica , Aorta , Humanos , Aorta Torácica/fisiologia , Aorta/fisiologia , Hemodinâmica/fisiologia , Estresse Mecânico , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo/fisiologia
16.
Int J Cardiol ; 386: 1-7, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37201616

RESUMO

AIMS: Spontaneous coronary artery dissection (SCAD) is an increasingly diagnosed cause of myocardial infarction with unclear pathophysiology. The aim of the study was to test if vascular segments site of SCAD present distinctive local anatomy and hemodynamic profiles. METHODS: Coronary arteries with spontaneously healed SCAD (confirmed by follow-up angiography) underwent three-dimensional reconstruction, morphometric analysis with definition of vessel local curvature and torsion, and computational fluid dynamics (CFD) simulations with derivation of time-averaged wall shear stress (TAWSS) and topological shear variation index (TSVI). The (reconstructed) healed proximal SCAD segment was visually inspected for co-localization with curvature, torsion, and CFD-derived quantities hot spots. RESULTS: Thirteen vessels with healed SCAD underwent the morpho-functional analysis. Median time between baseline and follow-up coronary angiograms was 57 (interquartile range [IQR] 45-95) days. In seven cases (53.8%), SCAD was classified as type 2b and occurred in the left anterior descending artery or near a bifurcation. In all cases (100%), at least one hot spot co-localized within the healed proximal SCAD segment, in 9 cases (69.2%) ≥ 3 hot spots were identified. Healed SCAD in proximity of a coronary bifurcation presented lower TAWSS peak values (6.65 [IQR 6.20-13.20] vs. 3.81 [2.53-5.17] Pa, p = 0.008) and hosted less frequently TSVI hot spots (100% vs. 57.1%, p = 0.034). CONCLUSION: Vascular segments of healed SCAD were characterized by high curvature/torsion and WSS profiles reflecting increased local flow disturbances. Hence, a pathophysiological role of the interaction between vessel anatomy and shear forces in SCAD is hypothesized.


Assuntos
Anomalias dos Vasos Coronários , Infarto do Miocárdio , Doenças Vasculares , Humanos , Vasos Coronários/diagnóstico por imagem , Doenças Vasculares/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Angiografia Coronária/efeitos adversos , Hemodinâmica
17.
J Mech Behav Biomed Mater ; 138: 105623, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36535095

RESUMO

Self-expandable transcatheter aortic valves (TAVs) elastically resume their initial shape when implanted without the need for balloon inflation by virtue of the nickel-titanium (NiTi) frame super-elastic properties. Experimental findings suggest that NiTi mechanical properties can vary markedly because of a strong dependence on the chemical composition and processing operations. In this context, this study presents a computational framework to investigate the impact of the NiTi super-elastic material properties on the TAV mechanical performance. Finite element (FE) analyses of TAV implantation were performed considering two different TAV frames and three idealized aortic root anatomies, evaluating the device mechanical response in terms of pullout force magnitude exerted by the TAV frame and peak maximum principal stress within the aortic root. The widely adopted NiTi constitute model by Auricchio and Taylor (1997) was used. A multi-parametric sensitivity analysis and a multi-objective optimization of the TAV mechanical performance were conducted in relation to the parameters of the NiTi constitutive model. The results highlighted that: five NiTi material model parameters (EA, σtLS, σtUS, σtUE and σcLS) are significantly correlated with the FE outputs; the TAV frame geometry and aortic root anatomy have a marginal effect on the level of influence of each NiTi material parameter; NiTi alloy candidates with pareto-optimal characteristics in terms of TAV mechanical performance can be successfully identified. In conclusion, the proposed computational framework supports the TAV design phase, providing information on the relationship between the super-elastic behavior of the supplied NiTi alloys and the device mechanical response.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Níquel , Titânio , Ligas , Estresse Mecânico
18.
Int J Cardiol ; 370: 356-365, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36343795

RESUMO

AIMS: Wall shear stress (WSS) is involved in coronary artery plaque pathological mechanisms and modulation of gene expression. This study aims to provide a comprehensive haemodynamic and biological description of unstable (intact-fibrous-cap, IFC, and ruptured-fibrous-cap, RFC) and stable (chronic coronary syndrome, CCS) plaques and investigate any correlation between WSS and molecular pathways. METHODS AND RESULTS: We enrolled 24 CCS and 25 Non-ST Elevation Myocardial Infarction-ACS patients with IFC (n = 11) and RFC (n = 14) culprit lesions according to optical coherence tomography analysis. A real-time PCR primer array was performed on peripheral blood mononuclear cells for 17 different molecules whose expression is linked to WSS. Computational fluid dynamics simulations were performed in high-fidelity 3D-coronary artery anatomical models for three patients per group. A total of nine genes were significantly overexpressed in the unstable patients as compared to CCS patients, with no differences between IFC and RFC groups (GPX1, MMP1, MMP9, NOS3, PLA2G7, PI16, SOD1, TIMP1, and TFRC) while four displayed different levels between IFC and RFC groups (TNFα, ADAMTS13, EDN1, and LGALS8). A significantly higher WSS was observed in the RFC group (p < 0.001) compared to the two other groups. A significant correlation was observed between TNFα (p < 0.001), EDN1 (p = 0.036), and MMP9 (p = 0.005) and WSS values in the RFC group. CONCLUSIONS: Our data demonstrate that IFC and RFC plaques are subject to different WSS conditions and gene expressions, suggesting that WSS profiling may play an essential role in the plaque instability characterization with relevant diagnostic and therapeutic implications in the era of precision medicine.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Ruptura Cardíaca , Placa Aterosclerótica , Humanos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/genética , Vasos Coronários/patologia , Leucócitos Mononucleares , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/genética , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/genética , Tomografia de Coerência Óptica/métodos , Ruptura Espontânea/metabolismo , Ruptura Espontânea/patologia , Angiografia Coronária/métodos , Galectinas/metabolismo
19.
IEEE Trans Biomed Eng ; 70(3): 1095-1104, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36155431

RESUMO

OBJECTIVE: The need for distilling the hemodynamic complexity of aortic flows into clinically relevant quantities resulted in a loss of the information hidden in 4D aortic fluid structures. To reduce information loss, this study proposes a network-based approach to identify and characterize in vivo the large-scale coherent motion of blood in the healthy human aorta. METHODS: The quantitative paradigm of the aortic flow as a "social network" was applied on 4D flow MRI acquisitions performed on forty-one healthy volunteers. Correlations between the aortic blood flow rate waveform at the proximal ascending aorta (AAo), assumed as one of the drivers of aortic hemodynamics, and the waveforms of the axial velocity in the whole aorta were used to build "one-to-all" networks. The impact of the driving flow rate waveform and of aortic geometric attributes on the transport of large-scale coherent fluid structures was investigated. RESULTS: The anatomical length of persistence of large-scale coherent motion was the 29.6% of the healthy thoracic aorta length (median value, IQR 23.1%-33.9%). Such length is significantly influenced by the average and peak-to-peak AAo blood flow rate values, suggesting a remarkable inertial effect of the AAo flow rate on the transport of large-scale fluid structures in the distal aorta. Aortic geometric attributes such as curvature, torsion and arch shape did not influence the anatomical length of persistence. CONCLUSION: The proposed in vivo approach allowed to quantitatively characterize the transport of large-scale fluid structures in the healthy aorta, strengthening the definition of coherent hemodynamic structures and identifying flow inertia rather than geometry as one of its main determinants. SIGNIFICANCE: The findings on healthy aortas may be used as reference values to investigate the impact of aortic disease or implanted devices in disrupting/restoring the physiological spatiotemporal coherence of large-scale aortic flow.


Assuntos
Aorta , Valva Aórtica , Humanos , Velocidade do Fluxo Sanguíneo , Aorta/diagnóstico por imagem , Imageamento por Ressonância Magnética , Aorta Torácica
20.
Front Bioeng Biotechnol ; 10: 1011806, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36568311

RESUMO

An experimental set-up is presented for the in vitro characterization of the fluid dynamics in personalized phantoms of healthy and stenosed coronary arteries. The proposed set-up was fine-tuned with the aim of obtaining a compact, flexible, low-cost test-bench for biomedical applications. Technically, velocity vector fields were measured adopting a so-called smart-PIV approach, consisting of a smartphone camera and a low-power continuous laser (30 mW). Experiments were conducted in realistic healthy and stenosed 3D-printed phantoms of left anterior descending coronary artery reconstructed from angiographic images. Time resolved image acquisition was made possible by the combination of the image acquisition frame rate of last generation commercial smartphones and the flow regimes characterizing coronary hemodynamics (velocities in the order of 10 cm/s). Different flow regimes (Reynolds numbers ranging from 20 to 200) were analyzed. The smart-PIV approach was able to provide both qualitative flow visualizations and quantitative results. A comparison between smart-PIV and conventional PIV (i.e., the gold-standard experimental technique for bioflows characterization) measurements showed a good agreement in the measured velocity vector fields for both the healthy and the stenosed coronary phantoms. Displacement errors and uncertainties, estimated by applying the particle disparity method, confirmed the soundness of the proposed smart-PIV approach, as their values fell within the same range for both smart and conventional PIV measured data (≈5% for the normalized estimated displacement error and below 1.2 pixels for displacement uncertainty). In conclusion, smart-PIV represents an easy-to-implement, low-cost methodology for obtaining an adequately robust experimental characterization of cardiovascular flows. The proposed approach, to be intended as a proof of concept, candidates to become an easy-to-handle test bench suitable for use also outside of research labs, e.g., for educational or industrial purposes, or as first-line investigation to direct and guide subsequent conventional PIV measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA